                                  Violation 0
********************************************************************************
title: WARNING: DRC doesn't catch everything
explanation: Detection of outright shorts, missing connections, etc.
is handled via rat's nest addition.  To catch these problems,
display the message log using Window->Message Log, then use
Connects->Optimize rats nest (O hotkey) and watch for messages.

location: (x, y) = (0, 0), angle = 0.000000
have_measured: true
measured value: 0
required value: 0
object count: 0
object IDs: 
object types: 

********************************************************************************
                                  Violation 1
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (4292223, 17119600), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 38 374 
object types: 512 16384 

********************************************************************************
                                  Violation 2
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (3340478, 18567400), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 375 128 
object types: 16384 512 

********************************************************************************
                                  Violation 3
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (4266823, 20015200), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 376 47 
object types: 16384 512 

********************************************************************************
                                  Violation 4
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (3378578, 21437600), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 377 137 
object types: 16384 512 

********************************************************************************
                                  Violation 5
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (9321423, 8509000), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 56 381 
object types: 512 16384 

********************************************************************************
                                  Violation 6
********************************************************************************
title: Potential for broken trace
explanation: Insufficient overlap between objects can lead to broken tracks
due to registration errors with old wheel style photo-plotters.
location: (x, y) = (9296023, 11379200), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 65 383 
object types: 512 16384 

********************************************************************************
                                  Violation 7
********************************************************************************
title: Potential for broken trace
explanation: Insufficient overlap between objects can lead to broken tracks
due to registration errors with old wheel style photo-plotters.
location: (x, y) = (9270623, 14249400), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 74 385 
object types: 512 16384 

********************************************************************************
                                  Violation 8
********************************************************************************
title: Potential for broken trace
explanation: Insufficient overlap between objects can lead to broken tracks
due to registration errors with old wheel style photo-plotters.
location: (x, y) = (8522078, 15697200), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 386 164 
object types: 16384 512 

********************************************************************************
                                  Violation 9
********************************************************************************
title: Potential for broken trace
explanation: Insufficient overlap between objects can lead to broken tracks
due to registration errors with old wheel style photo-plotters.
location: (x, y) = (8471278, 9931400), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 146 382 
object types: 512 16384 

********************************************************************************
                                  Violation 10
********************************************************************************
title: Potential for broken trace
explanation: Insufficient overlap between objects can lead to broken tracks
due to registration errors with old wheel style photo-plotters.
location: (x, y) = (8496678, 12801600), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 155 384 
object types: 512 16384 